Monitor GF 500 Manual de Serviço

Consulte online ou descarregue Manual de Serviço para Aquecedores elétricos Monitor GF 500. Monitor GF 500 Service manual Manual do Utilizador

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
Vista de página 0
MONITOR GF500
Vented
Heating System
Service
Manual
The
information
contained
herein
is
proprietary
to
Monitor
Products, Inc. shall
not be
disclosed,
duplicated,
nor
otherwise
copied
in
whote
or
part
for any
other purpose without
express
written permission
of the
Legal Department
of
Monitor Products,
toe.
This data
is
issued
to
authorized
Monitor Servicing Personnel
for
guidance
in the
installation
and
maintenance
of the
subject product
and is
intended
for use by
authorized
Monitor service personnel
only.
Further,
Monitor
Products,
Inc. reserves
the
right
to
make improvements
and
corrections
and to
alter
specifications
of
products
described
herein,
at any
time
without
prior
notice.
P.
O.
BOX3408
PRINCETON,
NEW
JERSEY
08543
Vista de página 0
1 2 3 4 5 6 ... 40 41

Resumo do Conteúdo

Página 1 - MONITOR GF500

MONITOR GF500Vented Heating SystemService Manual•The information contained herein is proprietary to Monitor Products, Inc. shall not be disclosed, dup

Página 2 - Contents

MONITOR HEATING SYSTEMSection 2: Installation2-3 FLUE PIPE CLEARANCES• Vent terminal must be located at least 3 feet above any forced air inlet locate

Página 3

MONITOR HEATING SYSTEMSection 2: Installation2-4 INSTALLING AN EXTENSION KITInstalling an Extension Kit requires theconstruction of an air line and th

Página 4 - Description

MONITOR HEATING SYSTEMSection 2: InstallationMax lengths and bends allowable usingextension kits.Extension kits are available in four differentlengths

Página 5

MONITOR HEATING SYSTEMSection 2: Installation2-5 GAS CONNECTION1.The gas supply line shall be gas-tight, sizedand so installed as to provide a supply

Página 6

MONITOR HEATING SYSTEMSection 2: Installation2-6 GAS CONVERSION PROCEDURE1. Replace the natural orifice with the LP orificewhich is included in the co

Página 7

MONITOR HEATING SYSTEMSection 3: Operationw3-1 INTRODUCTIONMonitor is an easy-to-operate vented gas heater.Routine operation features high BTU output,

Página 8

MONITOR HEATING SYSTEMSection 3: OperationFIGURE AND ITEM NOCONTROL OR INDICATOR.FUNCTIONFigure 3-1, Item 6RUN Indicator LightLights when heater is ru

Página 9

MONITOR HEATING SYSTEMSection 3: OperationFIGURE AND ITEM NOCONTROL OR INDICATOR.FUNCTIONFigure 3-2, Item 143rd Indicator LightPrograms 3rd automatic

Página 10 - Installation

MONITOR HEATING SYSTEMSection 3: OperationFIGURE AND ITEM NO CONTROL OR INDICATOR.FUNCTIONFigure 3-2, Item 22 AUTO push-buttonswitchPlaces heater in a

Página 11

MONITOR HEATING SYSTEMSection 3: Operation3-6 MANUAL HEATER OPERATIONOperation of the heater is under the direct controlof the user (heater will not o

Página 12 - LENGTHS

MONITOR HEATING SYSTEMTable of ContentsSection 1: Description Page 1-71-1 Specifications; 1-2 Special Features; 1-3 Safety Features; 1-4Munual Gas Val

Página 13

MONITOR HEATING SYSTEMSection 3: OperationC. Press HOUR and MINUTE push-buttonswitches to program 1 st desired time.IMPORTANT: Be sure to set the cloc

Página 14 - CONVERSION PROCEDURE

MONITOR HEATING SYSTEMSection 3: Operationw-3-11 RECOVERY FROM A POWER FAILUREFor the power interruption of up to 5 minutes, theset memory is kept and

Página 15 - Operation

3-14 OPERATION CONTROL SYSTEMGF500 OPERATION TIMING CHARTRELAY,TWAC,PHOTO TRIAC,OPERATIONALAMPLIFIER

Página 16

MONITOR HEATING SYSTEMSection 4: Maintenance / Servicing4-1 CLEANING THE CABINETWhen the cabinet is soiled, wipe it with a dampcloth. Restore the shin

Página 17

MONITOR HEATING SYSTEMSection 4: Maintenance / ServicingI. Reassembly by reversing the procedurefollowed during disassembly./^WARNING:Do not attempt t

Página 18

MONITOR HEATING SYSTEMSection 5: TroubleshootingGF500 Resistance ValuesCOMPONENTIgnition Transformer (connector E/E)Power Transformer (1)-Primary (AC

Página 19 - ECONOMY

MONITOR HEATING SYSTEMSection 5: TroubleshootingGF 500 Component Voltage ReadingsCOMPONENTThermistorAll readings taken withThermistorAir Pressure Swit

Página 20

MONITOR HEATING SYSTEMSection 5: TroubleshootingTEST POINT VOLTAGEAll readings take from EPOV.'^v. Operation^^-^^ ModeTest Point^^^TP1TP2TP3TP4TP

Página 21 - HEATING SYSTEM

1.GENERAL CHECKSIs power available in wall outlet ?Is power Plug inserted in wall outlet ?Has there been a power interruption ? (Display window shews

Página 22

\ I SYMPTOM I [ CHECK1 | | RESULT | | CHECK2 | | RESULT | [ CHECK3 ] | RESULT | | CHECK4 ] | RESULT | | CHECKS | | RESULT | | REASON ] [ CORRECTIVE ME

Página 23 - UNSATISFACTORY

MONITOR HEATING SYSTEMSection 1: Description1-7 BURNERThis burner is a Bunsen type with a speciallystructured flame port section, which shapes andposi

Página 24 - /^WARNING:

RESULT I | CHECK4 | RESULT | | CHECKS | RESULT | [ REASON I CORRECTIVE MEASURE\ [ SYMPTOM I | CHECK1 | RESULT [ [ CHECK2 | RESULT |Room temp. Setting

Página 25 - Troubleshooting

SYMPTOM | | CHECK1 | RESULT | | CHECK2 [ RESULT | | CHECK3 | RESULT | | CHECK4 | RESULT | | CHECKS | RESULT | | REASON | | CORRECTIVE MEASURE ]4.5.whe

Página 26

SYMPTOMCHECK1RESULTCHECK2) •INo operation, l-p Does 88:88displaywindow?I Plug in AC cord. INOTE:If problem is found to be in PCB,do not attamp to repa

Página 27

', I SYMPTOM [ | CHECK1 | RESULT | | CHECK2 | RESULT | | CHECK3 | | RESULT | [ CHECK4 | | RESULT | | CHECKS | | RESULT |REASONCORRECTIVE MEASUREI

Página 28

REASONCORRECTIVE MEASUREFailure of diode. (05)Failure of microprocessor. HC1)Failure olTR array. (1C 13)Failure o< diode. (028 D29)Failure of relay

Página 29

CHECKSCHECK4REASONFLAME ROD BYPASS CIRCUITFor testing purposes - A flame detector rod bypass circuit can be made up, consistingof 2 insulated alligato

Página 30

CHECKSCHECK4CHECKSREASON CORRECTIVE MEASUREConnect lOKflresisterat fol pins, andthen, set temperaturefrom Low to High.Is thereapprox 2.8VatTPB?1motor

Página 31

Section 5: TroubleshootingINDICATION OF FAILURE MODEDigital DisplayC n iC u iE 05E OBE !The Reason of IndicationAt pre-purge, Flame rod is sensingflam

Página 33

MONITOR HEATING SYSTEMSection 6: Electrical SystemWIRING DIAGRAMGAS CONTROLVALVESWITCH AND LAMPPCB'20VSOHaBLOWER MOTORJO,MICROCOMPVJi PC.8! i [i

Página 34

MONITOR HEATING SYSTEMSection 1: Description1-9 IGNITION PLUG UNITThe Electrode is applied high voltage, anddischarges to the Grounding Rod to ignite

Página 35 - MEASURE

MONITOR HEATING SYb i tMParts ListNO123456789101112131415161716192020-120-220-320-4212223242526272829303132PARTS NAMEADJUSTABLE LEGTRAYAIR SUPPLY HOSE

Página 36 - REASON CORRECTIVE

MONITOR HEATING SYSTEMParts ListMO.69707172737475767778798081828334858687888990919293949596979899100PARTS NAMECONTROL COVERFRONT COVERLAMP PANELSWITCH

Página 37

MONITOR HEATING SYSTEMSection 1: Descriptionw1-11 FLAME DETECTORAn Electrode which detects that the burner hasbeen ignited, using the flame as a condu

Página 38

MONITOR HEATING SYSTEMSection 1: Description1-16 AIR PRESSURE SWITCHThis switch consists of a rubber diaphragm whichsenses changes in air pressure (it

Página 39 - Electrical

1cAIR CIRCULATION FANFLUE PIPEINTAKE OUTDOOR AIR<={> EXHAUSTEXCHANGERCOMBUSTION CHAMBERAIR DAMPERCOMBUSTIONBLOWERFLAME DETECTORGAS CONTROL VALVE

Página 40 - Parts List

MONITOR HEATING SYSTEMSection 2: Installation2-1 NOTICE BEFORE INSTALLATIONThe heater must be installed by a qualified serviceperson according to this

Página 41

MONITOR HEATING SYSTEMSection 2: Installation2-2 HEATER INSTALLATIONIn choosing a location for the Heater, the followingguidelines must be considered: